VOGONS


First post, by FIN_K89i

User metadata
Rank Newbie
Rank
Newbie

hello i have a problem on my windows 3.11 machine on PCem i have setup it whit 486sx16 whit 8mb of ram but i had lowered it to 4mb but then i brougth it back at 8mb it cant load programs it gives me a krnl386.exe general security error or the programs dont lauch end i have to ctrl+alt+del to close that program or windows goese all stuck end i have to force it to reboot how i fix this?

Reply 1 of 8, by myne

User metadata
Rank Oldbie
Rank
Oldbie

It's emulated.
Just delete it and start again.
It's not worth anyones time to solve.

I built:
Convert old ASUS ASC boardviews to KICAD PCB!
Re: A comprehensive guide to install and play MechWarrior 2 on new versions on Windows.
Dos+Windows 3.11 auto-install iso template (for vmware)
Script to backup Win9x\ME drivers from a working install
Re: The thing no one asked for: KICAD 440bx reference schematic

Reply 2 of 8, by FIN_K89i

User metadata
Rank Newbie
Rank
Newbie
myne wrote on 2024-11-02, 03:51:

It's emulated.
Just delete it and start again.
It's not worth anyones time to solve.

but i dont want to reinstall everything there is another way?

Reply 3 of 8, by BitWrangler

User metadata
Rank l33t++
Rank
l33t++

Did you try deleting the swap file?

Unicorn herding operations are proceeding, but all the totes of hens teeth and barrels of rocking horse poop give them plenty of hiding spots.

Reply 4 of 8, by Robbbert

User metadata
Rank Member
Rank
Member

That occurred to me too, but you got in first.

Delete C:\386SPART.PAR after removing the System and Hidden attributes. Then have a look in the Windows folders for any file with .SWP extension and delete that too.

Reply 5 of 8, by jakethompson1

User metadata
Rank Oldbie
Rank
Oldbie

attrib -r -a -s -h is how we always remembered it back then

Reply 6 of 8, by myne

User metadata
Rank Oldbie
Rank
Oldbie

yup.
RASH
Youre the only other person I've seen who did it that way though.

I built:
Convert old ASUS ASC boardviews to KICAD PCB!
Re: A comprehensive guide to install and play MechWarrior 2 on new versions on Windows.
Dos+Windows 3.11 auto-install iso template (for vmware)
Script to backup Win9x\ME drivers from a working install
Re: The thing no one asked for: KICAD 440bx reference schematic

Reply 7 of 8, by Jo22

User metadata
Rank l33t++
Rank
l33t++

Norton Commander can display and delete hidden files, too.
Except if they're protected, like that DoubleSpace image file and its config files. Then, attrib has to be used.

"Time, it seems, doesn't flow. For some it's fast, for some it's slow.
In what to one race is no time at all, another race can rise and fall..." - The Minstrel

//My video channel//

Reply 8 of 8, by Azarien

User metadata
Rank Oldbie
Rank
Oldbie

Removing the "a" attribute has no purpose if you're going to delete the file anyways.